The best water quality store in Australia.

Ordered Support: 03 8324 0124

Track Your Order

All Categories

  • All Categories
  • Accessories
  • Calibration & Maintenance Solutions
  • Calibration Standards
  • Electrode Storage and Cleaning
  • pH Buffer Solutions
  • Conductivity Meter & TDS Meter
  • Bench Meters
  • Pocket Meters
  • Portable Meters
  • Dissolved Oxygen Meter
  • pH Meter & ORP Meter
  • Bench Meters
  • Monitors & Controllers
  • Pocket Meters
  • Portable Meters
  • Photometer and Colorimeter
  • Pools and Spas
  • Digital Refractometers
  • Electrodes and Probes
  • Handy Photometers
  • Pocket Testers
  • Portable Meters
  • Professional Photometers
  • Probe & Electrode
  • Refractometer
  • Smart Monitors and Controllers
  • Soil Test Kit
  • Thermometer
  • Turbidity Meter
  • Wine Lab Equipment
  • Mini Titrators
  • Photometers

Mi180 pH, ORP, conductivity, TDS and NaCl Laboratory Bench Meter

  • $1,990.00
  • Product Code: MM-Mi180
  • Availability:

Mi180 measures 6 different parameters: pH, ORP, EC, TDS (Total Dissolved Solids), percentage of NaCl and temperature in a variety of ranges. pH calibration can be performed in 3 points selectable between 7 memorized buffers, to provide a very accurate calibration curve even when testing different samples, where very wide differences in pH can be found. The auto-ranging feature for EC and TDS mea..

Tags: mi170, tds, bench, laboratory autoranging, con/tds/nacl/temp, meter, handy, photometers mi180, ph, , orp, , conductivity conductivity conductivity conductivity conductivity conductivity conductivity conductivity conductivity conductivity conductivity conductivity

Mi180 measures 6 different parameters: pH, ORP, EC, TDS (Total Dissolved Solids), percentage of NaCl and temperature in a variety of ranges.

pH calibration can be performed in 3 points selectable between 7 memorized buffers, to provide a very accurate calibration curve even when testing different samples, where very wide differences in pH can be found.

The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested sample.

All measurements can be temperature compensated at 20 or 25°C and the compensation coefficient is selectable by the user.

The automatic temperature compensation can also be disabled for measuring the actual conductivity value. The stability indicator on the LCD ensures accuracy. Conductivity readings are performed with the 4-ring probe supplied with the meter.

The GLP feature allows users to store and recall data on system status. PC compatible through an RS232 port or USB.

ORDERING INFORMATION

Mi180 is supplied complete with:
• MA917B/1 pH Electrode
• MA814DB/1 EC/TDS/NaCl/Temperature probe
• MA831R Temperature Probe
• MA9315 Electrode Holder
• M10004 pH 4.01 Sachet Buffer Solution
• M10007 pH 7.01 Sachet Buffer Solution
• M10010 pH 10.01 Sachet Buffer Solution
• M10016 Sachet Electrode Cleaning Solution
• Mi5200 Application Software
• MA9350 RS232 connection cable with 2 meters cable
• Graduate Pipet, 12 VDC Adapter & Instruction manual

 

SPECIFICATIONS

pH Range

-2.00 to 16.00 pH; -2.000 to 16.000 pH

mV Range

±699.9 mV; ±2000 mV

EC Range

0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm uncompensed EC*

TDS Range

0.0 to 14.99 mg/l (ppm); 15.0 to 149.9 mg/l (ppm); 150 to 1499 mg/l (ppm); 1.50 to 14.99 g/l (ppt); 15.0 to 100.0 g/l (ppt); up to 400.0 g/l actual TDS* (with 0.80 factor)

NaCl Range

0.0 to 400.0%

Temp Range

-20.0 to 120.0°C / -4.0 to 248.0°F

pH Resolution

0.01 pH; 0.001 pH

mV Resolution

0.1 mV; 1 mV

EC Resolution

0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm;

TDS Resolution

0.01 mg/l; 0.1 mg/l; 1.0 mg/l; 0.01 g/l; 0.1 g/l

NaCl Resolution

0.1%

Temp Resolution

0.1°C / 0.1°F

pH Accuracy

±0.01 pH; ±0.002 pH

mV Accuracy

±0.2 mV; ±1 mV

EC Accuracy

±1% of reading ±(0.05 µS/cm or 1 digit)

TDS Accuracy

±1% of reading ±(0.03 ppm or 1 digit)

NaCl Accuracy

±1% of reading

Temp Accuracy

±0.4°C / ±0.8°F

Rel mV Offset

±2000 mV

pH Calibration

1, 2 or 3 points calibration, with 7 memorized buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45)

EC Calibration

1 point slope calibration with 6 memorized solutions: (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 µS/cm, 80.0 µS/cm, 111.8 mS/cm)

NaCl Calibration

1 point, with MA9066 solution

Temp Calibration

2 point, at 0 and 50°C / 32 and 122°F

Temperature Compensation

automatic or manual, from -20.0 to 120.0°C / -4.0 to 248.0°FF

Temperature Coefficient

selectable from 0.00 to 6.00%/°C (EC and TDS only)

pH Electrodes & Temp Probe

MA814DB/1 & MA917B/1 & MA831R (included)

TDS Factor

0.40 to 0.80 (default value is 0.50)

Log on demand

up to 50 samples on each range (pH, mV, EC, TDS, NaCl)

GLP

last pH, EC, NaCl calibration data

PC Interface

RS232 / USB Opto-isolated

Environment

0 to 50°C / 32 to 122°F; max RH 95%

Power supply